Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443

  • Model:WRP2-440 WRP2-441 WRP2-442 WRP2-443
  • Structure:Output signal number :Double
  • Temperature:0~1600℃
  • Material:Pt-Rh 10-Pt
  • Connection :Fixed Flange
  • Others:Terminal type:Explosion proof type
  • Description:Double output signal,Fixed flange connection,explosion-proof type

Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443
 

Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 Brief Description

Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 is industrial assembly-type thermocouple with double output signal,fixed threaded connection, explosion-proof type terminal,Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 is used as a sensor to measure temperature, usually matched with display instruments, recording meter and electronic computer. Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 can directly measure temperature from 0℃ to 1600℃ of liquid, vapor, gas medium and solid surface during various production processes. In addition, Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 has the advantages of simple assembly, convenient replacement, pressure spring type temperature sensing element, good anti-vibration, wide measuring range, high mechanical strength, good pressure durability.
 

Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 Working principle 
Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 working principle: two conductors with different components are welded at both ends to form a loop, measuring temperature directly side is called measurement side, terminal side is called reference side. When the temperature between measurement side and reference side has a difference, it will generate heat in the loop current, then connected to the display instrument, And the instrument indicates the corresponding temperature value of the thermal electromotive force generated by the thermocouple. Thermocouple thermoelectric EMF will grow with the measurement temperature’s growth, The size of the thermal electromotive force is related to the temperature of both ends.Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 has nothing to do with the length, diameter of the thermode.
Junction box, protective tube, insulated casing, termals and thermal electodes form a basic structure of assembly-type thermocouple, with a variety of installation of fixtures. 


Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 Main technical parameter 
Temperature measurement range and tolerance

Thermocouple type

Code

Graduation

Measurement range℃

tolerance△t ℃

Pt Rh10-Pt 

WRP

S

Max Temp:0~1600
Working Temp:0~1300

±1.5℃ /±0.25%│t│

Note: “t” is absolute value of measured temperature of temperature-sensing element. 


Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 Thermal response time 
When the temperature appear step change, the thermocouple output variation is to the equivalent of 50% of the change, The time required is called the thermal response time “T0.5” 


The nominal pressure of Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443
Generally speaking, it is the static outside pressure which the protection tube can withstand without being broken in the room temperature. In fact, allowing working pressure is not only related to the protection tube material, the diameter and wall thickness, it is also related to its structure, the installation method, the into depth, the measured flow rate to its structure, the installation method, the into depth, the measured flow rate and the type of media.
The test voltage of the insulation resistance in room temperature is DC 500V±50V, The atmospheric conditions of measuring at the room temperature insulation resistance is 15~35℃ , relative humidity is 45% and atm pressure is 86~106kPa,
For thermocouples that is longer than 1 meters, the product of the resistance value at ambient-temperature and its length should be not less than 100.
Can be expressed as: Rr. L≧100MΩ.ML>1m
Rr here means the insulation resistance value of the thermocouple at ambient-temperature, the unit is MΩ.
For thermocouple of which the length is equal to/less than 1m small, its ambient temperature insulation resistance value shall not be less than 100MΩ. 
 

Upper-limit temperature of the insulation resistance 
The upper-limit temperature of the insulation resistance for thermocouple should not be less than the following provisions:


     Upper-limit temperature℃

Test temperature t℃

 Resistance value MΩ

100≤tm<300

t=tm

10

300≤tm<500

t=tm

2

500≤tm<850

t=tm

0.5

850≤tm<1000

t=tm

0.08

1000≤tm<1300

t=tm

0.02

tm>1300

t=1300

0.02


Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 Model


     WR

Thermocouple

Content

 

Code

Heat probe type

R

Pt-Rh30- Pt-Rh6

P

Pt-Rh 10-Pt

N

Nickel chromium-nickel silicon

M

Nickel chromium nickel silicon - silicon

E

Nickel chromium - nickel copper

C

Copper - Copper - Nickel

F

Iron copper nickel

 

Code

Output signal number

None
 2

     single
     double

Code

Fixed device form

 

     1
     2
     3
     4
     5
     6
     7

     Without fixed device
     Fixed threaded
     Movable flange
     Fixed flange
     Movable flange square
     Fixed thread conical
     Straight pipe joint type

Code

Terminal type

     2
     3
     4

     Splash proof
     Waterproof type
     Explosion proof type

 

Code

Protection tube diameter

0

Φ16mm

1

Φ25mm

2

Φ16mm

3

Φ20mm

If the fixed thread assembly-type Thermocouple WRP2-440 WRP2-441 WRP2-442 WRP2-443 for sale caters to your requirement, welcome to buy with us. As one of the leading such manufacturers and suppliers in China, we will offer you cheap price and excellent services.