Thermocouple manufacturer and supplier
  aires@shxvalve.com

contact us

SHANGHAI HUIXUAN INSTRUMENT

Mobile:+86-17717522891
Wechat:17717522891
Email:aires@shxvalve.com
 

Office Address: No.720 Suide Road,Jiading district,Shanghai,China
 

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433

  • Model:WRR2-430 WRR2-431 WRR2-432 WRR2-433
  • Structure:Output signal number :Double
  • Temperature:0~1800℃
  • Material:Pt-Rh30- Pt-Rh6
  • Connection :Fixed Flange
  • Others:Terminal type:Waterproof type
  • Description:Double output signal;Connection:Fixed flange;Waterproof type terminal

Thermocouple  WRR2-430 WRR2-431 WRR2-432 WRR2-433


Thermocouple  WRR2-430 WRR2-431 WRR2-432 WRR2-433 Brief Description

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 is WRR series assembly-type thermocouple is Double output signal,Fixed flange connection, waterproof  type terminal, temperature from 0℃ to 1800℃, Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 used as a sensor to measure temperature, usually matched with display instruments, recording meter and electronic computer.  Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 can directly measure temperature from 0℃ to 1800℃ of liquid, vapor, gas medium and solid surface during various production processes. In addition, Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR-433 has the advantages of simple assembly, convenient replacement, pressure spring type temperature sensing element, good anti-vibration, wide measuring range, high mechanical strength, good pressure durability.

 

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 Working principle

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 working principle: two conductors with different components are welded at both ends to form a loop, measuring temperature directly side is called measurement side, terminal side is called reference side. When the temperature between measurement side and reference side has a difference, it will generate heat in the loop current, then connected to the display instrument, And the instrument indicates the corresponding temperature value of the thermal electromotive force generated by the thermocouple. Thermocouple thermoelectric EMF will grow with the measurement temperature’s growth, The size of the thermal electromotive force is related to the temperature of both ends. It has nothing to do with the length, diameter of the thermode.

Junction box, protective tube, insulated casing, termals and thermal electodes form a basic structure of assembly-type thermocouple, with a variety of installation of fixtures.

 

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 Main technical parameter

Temperature measurement range and tolerance

Thermocouple type

Code

Graduation

Measurement range℃

tolerance△t ℃

Pt Rh30- Pt Rh6 

WRR

B

Max Temp:0~1800
Working Temp:0~1600

±1.5℃/±0.25%│t│

Note: “t” is absolute value of measured temperature of temperature-sensing element.

 

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 Thermal response time

When the temperature appear step change, the thermocouple output variation is to the equivalent of 50% of the change, The time required is called the thermal response time “T0.5”

 

The nominal pressure of Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433

Generally speaking, Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 is the static outside pressure which the protection tube can withstand without being broken in the room temperature. In fact, allowing working pressure is not only related to the protection tube material, the diameter and wall thickness, it is also related to its structure, the installation method, the into depth, the measured flow rate to its structure, the installation method, the into depth, the measured flow rate and the type of media.

 

The test voltage of the insulation resistance in room temperature is DC 500V±50V, The atmospheric conditions of measuring at the room temperature insulation resistance is 15~35℃, relative humidity is 45% and atm pressure is 86~106kPa,

For thermocouples that is longer than 1 meters, the product of the resistance value at ambient-temperature and its length should be not less than 100.

Can be expressed as: Rr. L≧100MΩ.ML>1m

Rr here means the insulation resistance value of the thermocouple at ambient-temperature, the unit is MΩ.

For thermocouple of which the length is equal to/less than 1m small, its ambient temperature insulation resistance value shall not be less than 100MΩ.

 

Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 Model 

WR

Thermocouple

Content

 

Code

Heat probe type

R

Pt-Rh30- Pt-Rh6

P

Pt-Rh 10-Pt

N

Nickel chromium-nickel silicon

M

Nickel chromium nickel silicon - silicon

E

Nickel chromium - nickel copper

C

Copper - Copper - Nickel

F

Iron copper nickel

 

Code

Output signal number

None
2

single
double

Code

Fixed device form

 

1
2
3
4
5
6
7

Without fixed device
Fixed threaded
Movable flange
Fixed flange
Movable flange square
Fixed thread conical
Straight pipe joint type

Code

Terminal type

2
3
4

Splash proof
Waterproof type
Explosion proof type

 

Code

Protection tube diameter

0

Φ16mm

1

Φ25mm

2

Φ16mm

3

Φ20mm

If Thermocouple WRR2-430 WRR2-431 WRR2-432 WRR2-433 of WRR series assembly-type thermocouple for sale caters to your requirement, welcome to buy with us. As one of the leading such manufacturers and suppliers in China, we will offer you cheap price and excellent services.

INQUIRY US

微信扫一扫

添加我为好友了解更多